DB2 - Problembeschreibung
Problem IC82710 | Status: Geschlossen |
IBM.DATA.DB2 CAN THROW A SYSTEM.INDEXOUTOFRANGEEXCEPTION OR SYST EM.INVALIDOPERATIONEXCEPTION WHEN ESTABLISHING CONNECTIONS | |
Produkt: | |
DB2 CONNECT / DB2CONNCT / 970 - DB2 | |
Problembeschreibung: | |
IBM.Data.DB2 can throw a System.IndexOutOfRangeException or System.InvalidOperationException when establishing a high # of connections at once with a high # of threads running in parallel. System.InvalidOperationException Stack: EX_1: Thread 26 Collection was modified; enumeration operation may not execute. at System.Collections.ArrayList.ArrayListEnumeratorSimple.MoveNext( ) at System.Data.Common.DbConnectionStringBuilder.get_ConnectionStrin g() at IBM.Data.DB2.DB2Permission.Add(String connectionString, String restrictions, KeyRestrictionBehavior behavior) at IBM.Data.DB2.DB2Connection.Open() at TransHang.SysSelect(Int32 threadn, String txtype) System.IndexOutOfRangeException Stack: EX_1: Thread 27 Index was outside the bounds of the array. at System.Collections.ArrayList.ArrayListEnumeratorSimple.MoveNext( ) at System.Data.Common.DbConnectionStringBuilder.get_ConnectionStrin g() at IBM.Data.DB2.DB2Permission.Add(String connectionString, String restrictions, KeyRestrictionBehavior behavior) at IBM.Data.DB2.DB2Connection.Open() at TransHang.SysSelect(Int32 threadn, String txtype) | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Windows users using MSDTC * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to 9.7 FP 7 or greater * **************************************************************** | |
Local-Fix: | |
You may set "SkipSynonymProcessing" connection string/db2dsdriver.cfg keyword to "true". The same can be achieved by setting "DB2ConnectionStringBuilder.SkipSynonymProcessing=true", if you use DB2ConnectionStringBuilder class to build the connection string. | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows | |
Lösung | |
Problem first fixed in DB2 Version 9.7 Fix Pack 7 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC88622 IT00978 IT00979 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 17.04.2012 30.10.2012 30.10.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP7 | |
Problem behoben lt. FixList in der Version | |
9.7.0.7 |