DB2 - Problem description

Problem IC74795 Status: Closed

MOUNT RESOURCE MONITOR TIMEOUT CAN CAUSE OTHER MOUNT MONITORS TO GET
INCORRECT LVM INFORMATION

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
If a mount monitor times out,  it can cause other mount monitors 
to get incorrect information from lsvg potentially causing an 
outage. 
The surviving mount monitor may get incorrect output from lsvg 
resulting in the monitor not recognizing a VG as being 
concurrent. The monitor will act as though the VG is 
non-concurrent, yet varied on, and may mount the file system it 
is monitoring. If this happens on a standby node while the mount 
resource is online on the primary, it can cause an outage as TSA 
brings resources offline on the primary node.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Smart Analytic System 7600                                   * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* If a mount monitor times out,  it can cause other mount      * 
* monitors                                                     * 
* to get incorrect information from lsvg potentially causing   * 
* an                                                           * 
* outage.                                                      * 
*                                                              * 
* The surviving mount monitor may get incorrect output from    * 
* lsvg                                                         * 
* resulting in the monitor not recognizing a VG as being       * 
*                                                              * 
* concurrent. The monitor will act as though the VG is         * 
*                                                              * 
* non-concurrent, yet varied on, and may mount the file system * 
* it                                                           * 
* is monitoring. If this happens on a standby node while the   * 
* mount                                                        * 
* resource is online on the primary, it can cause an outage as * 
* TSA                                                          * 
* brings resources offline on the primary node.                * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 V97 fp5                                       * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.03.2011
08.12.2011
08.12.2011
Problem solved at the following versions (IBM BugInfos)
9.7.FP5
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.5 FixList