DB2 - Problem description
Problem IC99778 | Status: Closed |
OCINUMBERTOTEXT AND OCINUMBERFROMTEXT RETURN INCORRECT VALUE WHEN THE FORMAT STRING IS 99999999999999.9999 | |
product: | |
DB2 COMMON CLIE / DBCMNCLNT / A50 - DB2 | |
Problem description: | |
Both OCINumberToText and OCINumberFromText return incorrect values when the format string is 99999999999999.9999. The problem has been occurring since DB2CI shipped which was DB2 V9.7 FP1. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All OS * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 V10.5 FP4 or higher * **************************************************************** | |
Local Fix: | |
available fix packs: | |
DB2 Cancun Release 10.5.0.4 (also known as Fix Pack 4) for Linux, UNIX, and Windows | |
Solution | |
First fixed in DB2 V10.5 FP4 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 03.03.2014 08.09.2014 08.09.2014 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) | |
10.5.0.4 |