Informix - Problem description
Problem IT08259 | Status: Closed |
DBSCHEMA ABORTS WHEN IWA EXTERNAL TABLE EXISTS | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
dbschema will abort when it finds an external table from an IWA load job that still exists within the database after the load job has been aborted or terminated for other reasons. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * IWA users that run dbschema utility while an external table * * resulting from a data mart load still exists. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local Fix: | |
Workarounds: - run dbschema for each table within the database - delete the external table, then run dbschema again | |
Solution | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 13.04.2015 30.12.2015 30.12.2015 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
12.10.xC6 |