Informix - Problem description
Problem IT08441 | Status: Closed |
LOCKING TEMPORARY TABLE CAUSES HDR PRIMARY TO CRASH | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Locking a temporary table in exclusive mode causes HDR primary to crash. 12:02:16 Assert Failed: No Exception Handler 12:02:16 IBM Informix Dynamic Server Version 12.10.FC5 12:02:16 Who: Session(69, informix@server, 12053, 0x44c36d78) Thread(98, sqlexec, 44bf80a8, 1) File: mtex.c Line: 508 12:02:16 Results: Exception Caught. Type: MT_EX_OS, Context: mem 12:02:16 Action: Please notify IBM Informix Techical Support. 12:02:16 See Also: /usr/informix/tmp/af.44a3118 12:02:17 Thread ID 98 will now be suspended. (oninit) afstack (oninit) mt_ex_throw_sig (oninit) afsig_handler (Linux) <signal frame> (/lib64/libc-2.5.so) __GI_strcpy (oninit) cloneLogTableLock (oninit) dolock_int (oninit) aud_dolock (oninit) excommand (oninit) sq_execute (oninit) sqmain (oninit) spawn_thread (oninit) th_init_initgls (oninit) startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of HDR, RSS and SDS clusters. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local Fix: | |
Solution | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 21.04.2015 30.12.2015 30.12.2015 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
12.10.xC6 |