Problem IT30297 Status: Closed

TIMESERIES DATA USING ROLLING WINDOW CONTAINERS: QUERY NOT RETURNING
CORRECT RESULTS UNDER CERTAIN CONDITIONS

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Time series container is defined as rolling window with 1 month
being the interval.  In the table for 7-31 there is no data
starting at midnight until 5:15 a.m.  Then data exists on it's
regular 15 minute interval into 8-1.  When running the following
query (where the time filter for the timeseries starts inside
the gap of missing data) no data is returned for 7-31 (even
though data exists) but the data for 8-1 is returned:

select * from vt_tab1 where rdng_dtmgmt >= "2019-07-31
01:00:00.00000" and rdng_dtmgmt = "2019-07-31
01:00:00.00000" and rdng_dtmgmt
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC3.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC3.           *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC3.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC3.           *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC14 and 14.10.xC3.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
16.09.2019
25.02.2020
25.02.2020
Problem solved at the following versions (IBM BugInfos)
12.10.xC14,
14.10.xC3
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download