Informix - Problem description

Problem IT31106 Status: Closed

It should not be possible to drop a row type that is being referenced in a
stored procedure.

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
The database server does not check for dependent stored
procedures while dropping a row type and will allow the row type
to be dropped.  A subsequent run of that SPL will fail with a
relevant error when the row type is encountered.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC4 (when      *
* available).                                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC14 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 12.10.xC14 or 14.10.xC4 (when      *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC14 and 14.10.xC4.  However, the
fix is disabled by default.  To enable the fix:

1) query current server SQL_DEF_CTRL value
> select * from sysmaster:sysconfig where
cf_name='SQL_DEF_CTRL';

cf_id         262
cf_name       SQL_DEF_CTRL
cf_flags      50368576
cf_original
cf_effective  0x44004b0
cf_default    0x44004b0

2) turn on bit 0x8000000; in this case that would be 0xc4004b0,
then set it with onmode:
onmode -wm SQL_DEF_CTRL=0xc4004b0
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
28.11.2019
28.02.2020
28.02.2020
Problem solved at the following versions (IBM BugInfos)
12.10.xC14,
14.10.xC4
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download