Informix - Problem description

Problem IT31494 Status: Closed

'CDR CHECK' SYNTAX PAGE STILL RESTRICTING --SINCE OPTION TO
'TIMESTAMP'/'DELETEWINS' CR, NOT MENTIONING NEW REPLCHECK FACILITY

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
On
https://www.ibm.com/support/knowledgecenter/en/SSGU8G_12.1.0/com
.ibm.erep.doc/ids_erp_295.htm

it's still stated, for --since option: "The replicate must be
using the time stamp or delete wins conflict resolution rule."

and later:
Check from a specific time with the --since option. If the
replicate uses the time stamp or delete wins conflict resolution
rule and you regularly check consistency, you can limit the data
that is checked to the data that was updated since the last
consistency check.

This needs to be extended by ", or the participating tables must
be defined with the WITH REPLCHECK option, so the update time
contained in ifx_replcheck can be used instead.  This would be
particularly useful if the check could rely on an index
containing the replication key plus the ifx_replcheck column."
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server documentation prior to the          *
* 12.10.xC15 release.                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server documentation prior to the          *
* 12.10.xC15 release.                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Comment
The documentation has been updated.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
13.01.2020
31.08.2021
31.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download