Informix - Problem description

Problem IT36149 Status: Closed

SCHAPI: [AUTO UPDATE STATISTICS EVALUATION 42-2] ERROR -1265 OVERFLOW
OCCURRED ON A DATETIME OR INTERVAL OPERATION.

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
With tables having data distributions info, in sysdistrib
catalog table, that's older than ca. 11 years and 5 months
(99999 hours), AUS would throw following error:

SCHAPI: [Auto Update Statistics Evaluation 42-2] Error -1265
Overflow occurred on a datetime or interval operation.

Reason seems to be an HOUR(5) limitation in an internal query
populating sysadmin:aus_work_coldist transient table,
aus_coldist_expired field (which is a BIGINT, so could easily
hold higher numbers.)
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Local Fix:
determine and manually drop such old distribution info
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.03.2021
23.08.2021
23.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download