Informix - Problem description

Problem IT37932 Status: Closed

EXCEPTION DURING QUERY OF SYSSQLSTAT TABLE MAY LEAD TO SESSION HANG

product:
INFORMIX SERVER / 5725A3900 / E10 - 
Problem description:
If an exception is raised during the processing of a query
relating to the sysmaster table syssqlstat the clean up
operation may result in a further exception resulting in a loop
of the sqlexec thread. At the same time other threads may become
blocked waiting on the session mutex.

As the problem thread is in a running state the stack obtained
via onstat may be unreliable. Use the onmode -X stack command or
an OS command such as pstack to obtain a stack:

sigprocmask()
mt_sighold()
mt_ex_throw_sig()
mt_ex_end_keep_var()
prsqlstat()
pstread()
rsread()
fmread()
readseq_single()
gettupl()
scan_next()
next_row.part()
get_first_row_from_producer()
group_open()
prepselect()
open_cursor()
sq_open()
sqmain()
spawn_thread()
th_init_initgls()
startup()

This problem is first seen in versions where IT35916 is fixed.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7.          *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7.          *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.08.2021
02.11.2021
02.11.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download