suche 36x36
  • Admin-Scout-small-Banner
           

    CURSOR Admin-Scout

    get the ultimate tool for Informix

    pfeil  
Latest versionsfixlist
14.10.xC10 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

Informix - Problem description

Problem IT39411 Status: Closed

COLMIN,COLMAX EXPLANATION NEEDS TO BE CHANGED

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Both IBM Informix - 12.10 and 14.10 needs changes.

Task 1:

https://www.ibm.com/docs/en/informix-servers/12.10?topic=tables-
syscolumns
https://www.ibm.com/docs/en/informix-servers/14.10?topic=tables-
syscolumns#ids_sqr_025


Explanation
colmin	INTEGER		Minimum column length (in bytes)
colmax	INTEGER		Maximum column length (in bytes)

needs to be changed to below,

==============>

Explanation
colmin	INTEGER		Hold the second-smallest value in a column
colmax	INTEGER		Hold the second-largest value in a column

----------------------------------------------------------------
--------------------------------------------------------------


Task 2:

https://www.ibm.com/docs/en/informix-servers/12.10?topic=syscolu
mns-storing-maximum-minimum-values
https://www.ibm.com/docs/en/informix-servers/14.10?topic=syscolu
mns-storing-maximum-minimum-values


The colmin and colmax values hold the second-smallest and
second-largest data values in the column, respectively.

needs to be changed to below,

==============>

The colmin and colmax are statistical values which give only the
second-smallest and second-largest value of a column at the time
of the last update statistics (and only for leading index
columns).
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.FC10.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.FC10.                       *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.FC10.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.FC10.                       *
****************************************************************
Comment
Fixed in Informix Server 14.10.FC10.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
15.12.2021
23.02.2023
23.02.2023
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs