Informix - Problem description

Problem IT42577 Status: Closed

CONVERSION HANGS WITH CONVERT THREAD WAITING ON SQCONVSCPT CONDITION AND
CONV_SCRIPT THREAD NO LONGER PRESENT

product:
INFORMIX SERVER / 5725A3900 / E10 - 
Problem description:
During a migration of an Instance from 12 to 14 the following
hung situation can be seen:

The convert thread will be waiting on the sqconvscpt condition
as shown by onstat -g ath and onstat -g con output:

onstat -g con:

IBM Informix Dynamic Server Version 14.10.FC8 -- Quiescent -- Up
05:07:06 -- 1830932 Kbytes

Conditions with waiters:
cid      addr             name               waiter   waittime
350      4c56a460         ReadAhead          52       107
417      44156c30         bp_cond            63       164
4034     4e258280         sqconvscpt         48       18356

onstat -g ath:

IBM Informix Dynamic Server Version 14.10.FC8 -- Quiescent -- Up
05:04:57 -- 1830932 Kbytes

Threads:
 tid     tcb              rstcb            prty status
vp-class       name
 48       4c3dd6b8         46e87da8         3    cond wait
sqconvscpt   9cpu         convert


convert thread would have following stack:

 yield_processor_mvp
 mt_wait
 call_external_sql_script
 dummyupds
 sql_cleanup_entity
 do_each_version_work
 generic_fw_main
 convertSM
 th_init_initgls
 startup

The thread responsible for waking this thread from this
condition is named conv_script.
So if there is no longer a conv_script thread in the onstat -g
ath output that could indicate this problem has been
encountered.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.xC9W1.               *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.xC9W1.                      *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.xC9W1.               *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.xC9W1.                      *
****************************************************************
Comment
Fixed in Informix Server 14.10.xC9W1.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
28.11.2022
06.03.2023
06.03.2023
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download