Informix - Problem description

Problem IT42601 Status: Closed

INSERT WITH A REMOTE SELECT PART USING A DATE/DATETIME SPL VARIABLE
RETURNS -201 FROM THE REMOTE SERVER

product:
INFORMIX SERVER / 5725A3900 / E10 - 
Problem description:
When I use a insert statement with a select from a remote table
and in the
select a local SPL variable is used with a certain datatype, the
insert returns
an error -201.

The SP has the following logic

create procedure mp () returning char (12);
  define v_col3 char (12);
  define v_col4 datetime year to fraction (3);

-- if v_col4  is used with a varchar or a char datatype the
error will not appear
  --define v_col4  char(30);

  let v_col3 = "A00000000001";
  let v_col4 = current;

-- error is produced here
  insert into tab2 (col3, col4) select v_col3, v_col4 from
rem@holgerk_p:tab1;

  return v_col3;
end procedure;
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.FC10. *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 (if available) or      *
* 14.10.FC10.                                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.FC10. *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 (if available) or      *
* 14.10.FC10.                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC16 and 14.10.FC10.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
01.12.2022
22.02.2023
22.02.2023
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download