suche 36x36
  • Admin-Scout-small-Banner
           

    CURSOR Admin-Scout

    get the ultimate tool for Informix

    pfeil  
Latest versionsfixlist
14.10.xC10 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

Informix - Problem description

Problem IT42794 Status: Closed

OPTIMIZING A STATEMENT NEXT AFTER A FAILED PREPARE OF A MULTI-STATEMENT
INSERT FAILED IN OPINIT

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
When a set of insert statement into different tables is used by
a SQL editor
GUI, the statements are prepared as a multi statement prepare.
Given there
is an error during the prepare because of a permission issue and
error is returned
correctly to the client , but the optimization of the very next
statement failed
in the optimizer

Example

insert into tab1 values ();
insert into tab1 values ();

insert into tab2 values (); -- error -275
insert into tab2 values (); -- error -275

insert into tab1 values ();

and so on. All the insert statements are executed in one step.
After then another statement is prepared which should run
successful but failed in optimization.


0x00000000014ddb8d (oninit) afstack
0x00000000014db549 (oninit) afhandler
0x00000000014d8282 (oninit) affail_interface
0x00000000014e0be4 (oninit) mt_ex_throw_sig
0x00000000014e2570 (oninit) afsig_handler
0x00007fb889156b10 (Linux) 
0x000000000084b0ad (oninit) opinit.constprop.82
0x0000000000844024 (oninit) op_opinit
0x0000000000808f6e (oninit) sqoptim
0x0000000000aa766e (oninit) bldstructs
0x0000000000aa74ea (oninit) sqcmd
0x0000000000aa6e1d (oninit) sq_prepare
0x0000000000b93b4e (oninit) sqmain
0x0000000001611759 (oninit) spawn_thread
0x00000000014cac93 (oninit) th_init_initgls
0x00000000015131af (oninit) startup
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.xC10. *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 or 14.10.xC10.         *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.xC10. *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 or 14.10.xC10.         *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC16 and 14.10.xC10.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
23.12.2022
15.05.2023
21.06.2023
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download