Informix - Problem description
Problem IT34089 | Status: Closed |
ONLOG DOES NOT WORK ON A FILE BEING CREATED WITH ONTAPE AND BACKUP/RESTORE FILTERS. | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
onlog can be used to read log files being saved with ontape. This will fail, if the backup has been created using a backup filter onlog will show the following error message. zip: stdin: invalid compressed data--format violated Write failed on parent's output pipe. errno = 32.Error reading from tape device, Error No. = 0. when trying to read a logical log file compressed with gzip, A similar error will occur for other compression tools. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC5. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Informix Server 14.10.xC5. * **************************************************************** | |
Local Fix: | |
The backup is readable using an onlog from version 12.10 when using the right restore filter. | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC5. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Informix Server 14.10.xC5. * **************************************************************** | |
Comment | |
Fixed in Informix Server 14.10.xC5. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 02.09.2020 07.12.2020 07.12.2020 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |