Problem IC62500 Status: Geschlossen

INDPTR OF TYPE SQLLEN IS NOT REALLY RETURNING 64 BIT LENGTH.

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
The issue is on the SQLLEN handling inside the ODBC driver. 
On Windows 64 BIT platform, DB2 64-bit ODBC driver 
mishandles the array of SQLLEN data as an array of 32-bit 
integer rather than an array of 64-bit integer, so the DB2 
ODBC driver and database server would think that bind 
parameter is SQL_DATA_AT_EXEC type of bind parameter for the 
case of batch insert, although none of the array bind 
parameter is in that type.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users using IBM Data Server Client 9.5 on 64-bit         * 
* WindowsServer.                                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* The issue is on the SQLLEN handling inside the ODBC          * 
* driver.On Windows 64 BIT platform, DB2 64-bit ODBC           * 
* drivermishandles the array of SQLLEN data as an array of     * 
* 32-bitinteger rather than an array of 64-bit integer, so the * 
* DB2ODBC driver and database server would think that          * 
* bindparameter is SQL_DATA_AT_EXEC type of bind parameter for * 
* thecase of batch insert, although none of the array          * 
* bindparameter is in that type.                               * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Apply FP5 to solve the issue.                                * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 6a for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
The issue is first fixed in FP5 of V9.5.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC62503 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
12.08.2009
23.02.2010
23.02.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.
Problem behoben lt. FixList in der Version