DB2 - Problembeschreibung
Problem IC64047 | Status: Geschlossen |
USING CONTROL CENTER TO DO A REDIRECTED RESTORE MAY RESULT IN A SQL0902C IF THE ORIGINAL DRIVE LOCATION DOES NOT EXIST. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
When using the Control Center to restore a database from another server, if the orignal database resided on a different drive, then the restore will fail with a SQL0902C error. For example: Server A has Database SAMPLE defined on the D: drive. Server B only has a C: drive When trying to restore a backup from Server A onto Server B, the restore fails with a SQL0902C. The Control Center generates a backup statement with: RESTORE DATABASE SAMPLE FROM "C:\DB2_01\Backup" TAKEN AT 20090218043023 TO "C:" INTO SAMPLE2 WITH 2 BUFFERS BUFFER 1024 PARALLELISM 1 WITHOUT PROMPTING | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Windows Users * **************************************************************** * PROBLEM DESCRIPTION: * * When using the Control Center to restore a database from * * another * * server, if the orignal database resided on a different * * drive, * * then the restore will fail with a SQL0902C error. * * * * * * * * For example: * * * * Server A has Database SAMPLE defined on the D: drive. * * * * * * * * Server B only has a C: drive * * * * * * * * When trying to restore a backup from Server A onto Server B, * * the * * restore fails with a SQL0902C. * * * * * * * * The Control Center generates a backup statement with: * * * * * * * * RESTORE DATABASE SAMPLE FROM "C:\DB2_01\Backup" TAKEN AT * * * * 20090218043023 TO "C:" INTO SAMPLE2 WITH 2 BUFFERS * * * * BUFFER 1024 PARALLELISM 1 WITHOUT PROMPTING * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 9.7 Fixpak 1. * **************************************************************** | |
Local-Fix: | |
db2 RESTORE DATABASE SAMPLE FROM "C:\DB2BKUP" ON "C:\" WITH 1 BUFFERS BUFFER 1024 redirect PARALLELISM 1 WITHOUT PROMPTING | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows | |
Lösung | |
Problem first fixed in DB2 Version 9.7 fixpak 1. | |
Workaround | |
Use the following restore command outside of Control Center: db2 RESTORE DATABASE SAMPLE FROM "C:\DB2BKUP" ON "C:\" WITH 1 BUFFERS BUFFER 1024 redirect PARALLELISM 1 WITHOUT PROMPTING | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 22.10.2009 08.02.2010 08.02.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7. | |
Problem behoben lt. FixList in der Version | |
9.7.0.1 |