DB2 - Problembeschreibung
Problem IC64385 | Status: Geschlossen |
OPTIMIZATION PROFILES WITH SCHEMA NAMES CONTAINING # CHARACTERS WILL REPORT EXP0037W IN THE EXPLAIN EXTENDED DIAGNOSTIC SECTION | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
The following STMTKEY in a optimization profile, where the SCHEMA name contains a # character: <STMTKEY SCHEMA="S#AMPLE"> ... </STMTKEY> Reports EXP0037W in the generated db2expln output: Extended Diagnostic Information: -------------------------------- Diagnostic Identifier: 1 Diagnostic Details: EXP0037W Invalid setting request. The schema at line "2", column "31" is not a correct identifier (schema names should not have leading or traling white spaces unless delimited strings). Nevertheless, the optimization profile is applied for the given SQL statement. | |
Problem-Zusammenfassung: | |
USERS AFFECTED: All PROBLEM DESCRIPTION: See ERROR DESCRIPTION PROBLEM SUMMARY: See ERROR DESCRIPTION | |
Local-Fix: | |
Delimit the SCHEMA name with " in the optimization profile, when it contains a # character: <STMTKEY SCHEMA=""S#AMPLE""> | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in Version 9.7 Fix Pack 3. | |
Workaround | |
See LOCAL FIX. | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 06.11.2009 24.09.2010 24.09.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP3 | |
Problem behoben lt. FixList in der Version | |
9.7.0.3 | |