DB2 - Problembeschreibung
Problem IC66269 | Status: Geschlossen |
ROLLBACK IS NOT ALLOWED TO ROLLBACK BEYOND BEGINNING OF ANONYMOUS BLOCK | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
While executing a PL/SQL anonymous block (or SQL PL compiled compound statement), you will obtain error SQL0751N in the following situations: - The anonymous block contains a ROLLBACK statement. - The anonymous block invokes a routine that causes a ROLLBACK statement to be executed. For example: begin rollback; end; / DB21034E The command was processed as an SQL statement because it was not a valid Command Line Processor command. During SQL processing it returned: SQL0751N Routine "SYSIBMINTERNAL.COMPILED_ANON_BLOCK_INVOKE" (specific name "SQL100310140808540") attempted to execute a statement that is not allowed. create or replace procedure P is begin rollback; end; / begin p; end; / DB21034E The command was processed as an SQL statement because it was not a valid Command Line Processor command. During SQL processing it returned: SQL0751N Routine "MYSCHEMA.P" (specific name "P") attempted to execute a statement that is not allowed. This behaviour is a known limitation in DB2 Version 9.7. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL. * **************************************************************** * PROBLEM DESCRIPTION: * * See the APAR description. * **************************************************************** * RECOMMENDATION: * * Upgrade DB2 UDB version 9.7 fix pack 2. * **************************************************************** | |
Local-Fix: | |
Convert the anonymous block to a stored procedure, and invoke the procedure using CALL. For example: create or replace procedure Q is begin p; end; / call Q; drop procedure Q; | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in DB2 UDB Version 9.7 Fix Pack 2. | |
Workaround | |
See LOCAL FIX. | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC67297 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 11.02.2010 17.05.2010 17.05.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP2 | |
Problem behoben lt. FixList in der Version | |
9.7.0.2 |