DB2 - Problembeschreibung

Problem IC67571 Status: Geschlossen

EVENT MONITOR CAN TRAP IF EVENT MONITOR ENTRY IN THE DB2 SYSTEM CATALOG HAS
INCORRECT VALUE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Write to table event monitor can trap if event monitor entry in 
the DB2 system catalog has incorrect value. 
 
The trap file can contain the following callstack. 
 
sqmEvmonWriter 
sqm_evmon_mgr::start_evmon 
sqm_evmon_mgr::getAutostartEvmons 
sqm_evmon_mgr::autostartEvmons 
sqlm_a_init6 
sqeApplicatio::InitEngineComponents 
sqeApplication::AppStartUsing 
sqleSubAgentStartUsing 
sqeApplication::AppSecondaryStartUsing
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All platform.                                                * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* Write to table event monitor can trap if event monitor entry * 
* in the DB2 system catalog has incorrect value.               * 
*                                                              * 
* The trap file can contain the following callstack.           * 
*                                                              * 
* sqmEvmonWriter                                               * 
* sqm_evmon_mgr::start_evmon                                   * 
* sqm_evmon_mgr::getAutostartEvmons                            * 
* sqm_evmon_mgr::autostartEvmons                               * 
* sqlm_a_init6                                                 * 
* sqeApplicatio::InitEngineComponents                          * 
* sqeApplication::AppStartUsing                                * 
* sqleSubAgentStartUsing                                       * 
* sqeApplication::AppSecondaryStartUsing                       * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V9.7 FP2.                                         * 
****************************************************************
Local-Fix:
Drop the event monitor and create the event monitor using the 
same table.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
DB2 V9.7 FP2 will contain the fix.
Workaround
keiner bekannt / siehe Local-Fix