DB2 - Problembeschreibung
Problem IC68697 | Status: Geschlossen |
FCM SENDER IS NOT SELECTING DESIGNATED NETWORK INTERFACE TO SEND DATA | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
If multiple network interfaces are available on a machine with multiple logical partitions (MLNs), and each logical partition is specified to use a designated network interface for inter-partition communication (ie, via the netname column in db2nodes.cfg), DB2 may not choose the designated network interface to send data across partitions; it would instead let the operating system (OS) choose interfaces that are deemed appropriate to use. Depending on the actual workloads, this behavior can potentially be suboptimal for send traffic if the OS chose a single interface (or only a small subset) for all logical partitions rather than fully utilizing all available ones. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All of these criteria must be present for the problem to * * occur: * * - DPF * * - MLNs * * - multiple network interfaces on a machine * * - user configured each logical partition to use a different * * network interface (ie, via the netname column in * * db2nodes.cfg). * **************************************************************** * PROBLEM DESCRIPTION: * * If multiple network interfaces are available on a machine * * with * * multiple logical partitions (MLNs), and each logical * * partition * * is specified to use a designated network interface for * * * * inter-partition communication (ie, via the netname column in * * * * db2nodes.cfg), DB2 may not choose the designated network * * * * interface to send data across partitions; it would instead * * let * * the operating system (OS) choose interfaces that are deemed * * * * appropriate to use. Depending on the actual workloads, this * * * * behavior can potentially be suboptimal for send traffic if * * the * * OS chose a single interface (or only a small subset) for all * * * * logical partitions rather than fully utilizing all available * * * * ones. * **************************************************************** * RECOMMENDATION: * * Upgrade to v97fp3 or later. * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in v97fp3. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC68775 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 18.05.2010 16.09.2010 16.09.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP3 | |
Problem behoben lt. FixList in der Version | |
9.7.0.3 | |
9.7.0.3 |