DB2 - Problembeschreibung
Problem IC69232 | Status: Geschlossen |
DB2PD -DBCFG AND GET DB CFG SHOW DETAIL WILL ALWAYS DISPLAY 0 AS CURRENT VALUE FOR LOGSECOND, WHEN IT SHOULD BE -1 | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
A database configured for infinite active logging, by having LOGSECOND set to -1, will display the current in-memory value for LOGSECAND always as 0, even after recycling the instance or database. The following commands show the behavior: * db2pd -db <dbname> -dbcfg * db2 get db cfg for <dbname> show detail Due to the difference between the in-memory value and the database config file value, CallCenter will report "effective after database restart". | |
Problem-Zusammenfassung: | |
USERS AFFECTED: All PROBLEM DESCRIPTION: See ERROR DESCRIPTION PROBLEM SUMMARY: See ERROR DESCRIPTION | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in Version 9.7 Fix Pack 3. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 15.06.2010 24.09.2010 24.09.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP3 | |
Problem behoben lt. FixList in der Version | |
9.7.0.3 | |
9.7.0.3 |