DB2 - Problembeschreibung

Problem IC69271 Status: Geschlossen

ALTER TABLE OPERATION MAY LEAVE THE TABLE IN ALTER PENDING STATE AND
RETURN SQL0668N RC=8 EVEN IF DB2 HAS BEEN RESTARTED.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
In some rare cases, where a tables column has been altered to 
change the column 
type or length or perhaps changed from NOT NULL to a Nullable 
column, we may leave 
table still in alter pending status.  Even if the application 
is no longer around, or you have tried to restart the instance 
and go through 
crash recovery.  Any access to the table would return SQL0668N 
RC=8.
Problem-Zusammenfassung:
In some rare cases, where a tables column has been altered to 
change the column 
type or length or perhaps changed from NOT NULL to a Nullable 
column, we may leave 
table still in alter pending status.  Even if the application 
is no longer around, or you have tried to restart the instance 
and go through 
crash recovery.  Any access to the table would return SQL0668N 
RC=8.
Local-Fix:
Commiting every ALTER operation would work around this issue.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
apar fixed >= v97 fpk3
Workaround
Commiting every ALTER operation would work around this issue.
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC69581 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
16.06.2010
23.09.2010
23.09.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FPk3
Problem behoben lt. FixList in der Version
9.7.0.3 FixList
9.7.0.3 FixList