home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Neueste VersionenFixList
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

DB2 - Problembeschreibung

Problem IC69453 Status: Geschlossen

HEALTH MONITOR PROVIDES ALERT WHEN MONITOR HEAP SET TO AUTOMATIC.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Alert shows: 
 
ADM10500E Health indicator "Monitor Heap Utilization" 
("db2.mon_heap_util") breached the 
"upper" alarm threshold of "XX %" with value "XXX %" on 
"instance" "DB2". Calculation: 
 
Health Monitor is sending Alert to db2 user while Monitor Heap 
is set to Automatic. This APAR will fix the code in such a way 
that 
the health monitor code , by default will not monitor these 
health indicators. For those users who don't have the 
MON_HEAP_SZ 
to 'AUTOMATIC' and they want these health indicator alarms, they 
can enable using   "update alert cfg "  command.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* HEALTH MONITOR PROVIDES ALERT WHEN MONITOR HEAP SET TO       * 
* AUTOMATIC.                                                   * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Problem First fixed in DB2 V9.7 FP 4                         * 
****************************************************************
Local-Fix:
You can turn off the Monitor Alert switch by doing following: 
 
db2 update alert cfg for database manager using 
db2.mon_heap_util  set  THRESHOLDSCHECKED  NO 
db2 update alert cfg for databases using db.db_heap_util  set 
THRESHOLDSCHECKED  NO
Lösung
Alert shows: 
 
ADM10500E Health indicator "Monitor Heap Utilization" 
("db2.mon_heap_util") breached the 
 
"upper" alarm threshold of "XX %" with value "XXX %" on 
 
"instance" "DB2". Calculation: 
 
 
Health Monitor is sending Alert to db2 user while Monitor Heap 
is set to Automatic. This APAR will fix the code in such a way 
that 
the health monitor code , by default will not monitor these 
health indicators. For those users who don't have the MON_HEAP 
to 'AUTOMATIC' and they want these health indicator alams, they 
can enable using  "update alert cfg "  command.
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
24.06.2010
29.04.2011
26.10.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP4
Problem behoben lt. FixList in der Version