DB2 - Problembeschreibung
Problem IC72591 | Status: Geschlossen |
WHEN ATTACHING DEBUGGER TO THE DB2SYSCS PROCESS, DB2SYSCS CRASHES WITH STACK OVERFLOW. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
When attaching a Windows debugger (e.g. ADPlus, Windbg ) to the db2syscs process, the db2syscs process crashes in the debugger thread with STACK OVERFLOW exception. This happens to x64 versions of v97GA, v97fp1, v97fp2 and v97fp3. This does not happen to x86 32 bit versions of DB2. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 for X64 Windows * **************************************************************** * PROBLEM DESCRIPTION: * * When attaching a Windows debugger (e.g. ADPlus, Windbg ) to * * the * * db2syscs process, the db2syscs process crashes in the * * debugger * * thread with STACK OVERFLOW exception. * **************************************************************** * RECOMMENDATION: * * Apply v97fp4 * **************************************************************** | |
Local-Fix: | |
No workaround. Do not use the debugger to attach to the db2syscs.exe for these versions of DB2. | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows | |
Lösung | |
This problem was first fixed in v97fp4 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC72647 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 15.11.2010 28.04.2011 28.04.2011 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP4 | |
Problem behoben lt. FixList in der Version | |
9.7.0.4 |