DB2 - Problembeschreibung

Problem IC72797 Status: Geschlossen

DATABASE CONFIGURATION PARAMETER HADR_PEER_WINDOW RESET TO 0 DURING
DATABASE UPGRADE TO DB2 VERSION 9.7

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
During database migration to DB2 V9.7 database configuration 
parameter HADR_PEER_WINDOW gets reset to the default value (0). 
 
You need to set the original value manually after database 
upgrade finished successfully to ensure any cluster manager 
 
software relying on peer window functionality will work 
correctly after the upgrade.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Problem Description above.                               * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 Version 9.7 Fix Pack 5.                       * 
****************************************************************
Local-Fix:
Update database configuration manually after database upgrade. 
 
db2 update db cfg for <DB_NAME> using HADR_PEER_WINDOW <numeric 
value>
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 Version 9.7 Fix Pack 5.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC72852 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
24.11.2010
08.12.2011
08.12.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP5
Problem behoben lt. FixList in der Version
9.7.0.5 FixList