DB2 - Problembeschreibung
Problem IC72831 | Status: Geschlossen |
IN APPLICATION SNAPSHOT TP MONITOR OUTPUT CAN TRUNCATE | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 950 - DB2 | |
Problembeschreibung: | |
The following elements in application snapshot can be truncated, if application set these values frequently with different sizes using sqleseti api or CLI/Java keywords and if application and database are on different codepage. TP Monitor client user ID TP Monitor client workstation name TP Monitor client application name TP Monitor client accounting string | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 LUW Server * **************************************************************** * PROBLEM DESCRIPTION: * * The following elements in application snapshot can be * * truncated, if application set these values frequently with * * different sizes. * * * * * * TP Monitor client user ID * * TP Monitor client workstation name * * TP Monitor client application name * * TP Monitor client accounting string * **************************************************************** * RECOMMENDATION: * * Upgrade to v9.5fp7. * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.5 Fix Pack 7 for Linux, UNIX, and Windows | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC72832 IC72833 IC72857 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 26.11.2010 20.12.2010 20.12.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.5.FP7 | |
Problem behoben lt. FixList in der Version | |
9.1.0.7 | |
9.5.0.7 |