DB2 - Problembeschreibung
Problem IC73382 | Status: Geschlossen |
SQL0901N/SQL16074N XML SUBTYPE IS NOT INITIALIZED WHEN CALLING STORED PROCEDURE | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
Calling a SQL stored procedure using XML may return SQL0901/SQL16074 when its package is bound using REOPT=ALWAYS. SQL0901N The SQL statement failed because of a non-severe system error. Subsequent SQL statements can be processed. (Reason "XML subtype is not initialized".) SQL16074N An XQuery atomic value with the lexical representation starting with " " of type "xs:string" cannot be processed in the XQuery operation or function "xs:float()" because the length exceeds the operation or function limit of "30" bytes. | |
Problem-Zusammenfassung: | |
See ERROR DESCRIPTION. | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows | |
Lösung | |
Problem first fixed in v9.7 Fixpack 4. At minimum this fix should be applied to the server. | |
Workaround | |
See LOCAL FIX. | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC73389 IC73390 IC73392 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 18.12.2010 30.06.2011 30.06.2011 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP4 | |
Problem behoben lt. FixList in der Version | |
9.7.0.4 | |
9.7.0.5 |