DB2 - Problembeschreibung

Problem IC74536 Status: Geschlossen

STMM TUNING CHANGES FAIL FREQUENTLY IN DPF ENVIRONMENTS

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
Errors in STMM assumptions during the final validation stage 
cause tuning changes to fail unnecessarily in a DPF environment. 
This forces a rollback of successfully applied tuning changes 
across all partitions. 
These errors may be repetitive - they may occur every tuning 
cycle for long periods of time. 
Note that in cases of very disparate memory usage across 
partitions/nodes, these errors may be expected, as STMM does not 
tune non-homogenous partition groups effectively 
 
Example db2diag.log entries: 
 
2010-12-01-01.53.47.222586-300 E5004760A640       LEVEL: Warning 
PID     : 1929398              TID  : 47742       PROC : db2sysc 
7 
INSTANCE: db2inst1               NODE : 007         DB   : 
SAMPLE 
APPHDL  : 3-53                 APPID: *N3.DB2.101024132210 
AUTHID  : db2inst1 
EDUID   : 47742                EDUNAME: db2agntp (SAMPLE) 7 
FUNCTION: DB2 UDB, Self tuning memory manager, 
stmmCheckIfFreeMemoryIsEnoughForSizeIncr, probe:663 
MESSAGE : ZRC=0xFFFFEC49=-5047 
DATA #1 : String, 147 bytes 
There is not enough free memory for size increase. Free memory 
in pages: Physical memory = 4838, Instance memory = 314147, 
Database memory = 265040 
 
2010-12-01-01.53.47.230116-300 I5005901A850       LEVEL: Error 
PID     : 1929398              TID  : 47742       PROC : db2sysc 
7 
INSTANCE: db2inst1               NODE : 007         DB   : 
SAMPLE 
APPHDL  : 3-53                 APPID: *N3.DB2.101024132210 
AUTHID  : db2inst1 
EDUID   : 47742                EDUNAME: db2agntp (SAMPLE) 7 
FUNCTION: DB2 UDB, config/install, sqlfPdbUpdResetDbCfg, 
probe:1571 
MESSAGE : ZRC=0xFFFFEC49=-5047 
DATA #1 : SQLCA, PD_DB2_TYPE_SQLCA, 136 bytes 
 sqlcaid : SQLCA     sqlcabc: 136   sqlcode: -5047   sqlerrml: 0 
 sqlerrmc: 
 sqlerrp : SQL09055 
 sqlerrd : (1) 0x00000000      (2) 0x00000000      (3) 
0x00000000 
           (4) 0x00000000      (5) 0x00000000      (6) 
0x00000007 
 sqlwarn : (1)      (2)      (3)      (4)        (5)       (6) 
           (7)      (8)      (9)      (10)        (11) 
 sqlstate: 
 
2010-12-01-01.53.47.718020-300 I5031657A911       LEVEL: Error 
PID     : 1904822              TID  : 3600        PROC : db2sysc 
3 
INSTANCE: db2inst1               NODE : 003         DB   : 
SAMPLE 
APPHDL  : 3-53                 APPID: *N3.DB2.101024132210 
AUTHID  : db2inst1 
EDUID   : 3600                 EDUNAME: db2stmm (SAMPLE) 3 
FUNCTION: DB2 UDB, config/install, sqlfPdbUpdDbCfgReq, 
probe:1246 
DATA #1 : SQLCA, PD_DB2_TYPE_SQLCA, 136 bytes 
 sqlcaid :           sqlcabc: 0   sqlcode: -5124   sqlerrml: 1 
 sqlerrmc: 1 
 sqlerrp : 
 sqlerrd : (1) 0x00000000      (2) 0x00000000      (3) 
0x00000000 
           (4) 0x00000000      (5) 0x00000000      (6) 
0x00000007 
 sqlwarn : (1)      (2)      (3)      (4)        (5)       (6) 
           (7)      (8)      (9)      (10)        (11) 
 sqlstate: 
DATA #2 : String, 74 bytes 
Number of failed nodes: 61 
Nodes that failed: 4, 5, 6, 9, 10, and others.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DPF systems configured with STMM tuning Database_Memory      * 
* (SELF_TUNING_MEM = ON AND DATABASE_MEMORY = AUTOMATIC)       * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 Version 9.5 Fix Pack 8 or higher, or disable  * 
* STMM in DPF environments.                                    * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem first fixed in DB2 Version 9.5 Fix Pack 8
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC74680 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
17.02.2011
12.08.2011
12.08.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.5.FP8
Problem behoben lt. FixList in der Version
9.5.0.8 FixList