DB2 - Problembeschreibung

Problem IC74888 Status: Geschlossen

ADM4500W - PACKAGE CACHE OVERFLOW MESSAGE GETS LOGGED AS ERROR IN WINDOWS
EVENT LOGS.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Starting from DB2 V95, a package cache overflow warning message 
gets logged in as ERROR in Windows Event logs as follows. 
 
Event Type: Error 
Event Source: DB2-0 
Event Category: None 
Event ID: 4 
Date: 21.02.2011 
Time: 08:00:02 
User: N/A 
Computer: S-BDB02 
Description: 
2011-02-21-08.00.02.327007 Instance:DB2 Node:000 
PID:5716(db2syscs.exe) TID:200 Appid:*LOCAL.DB2.110221072654 
access plan manager sqlra_cache_mem_please Probe:100 
Database:VUINDEX 
ADM4500W A package cache overflow condition has occurred. There 
is no error but this indicates that the package cache has 
exceeded the configured maximum size. If this condition 
persists, you should perform additional monitoring to determine 
if you need to change the PCKCACHESZ DB configuration parameter. 
You could also set it to AUTOMATIC. 
 
It should get logged in as WARNING in the Windows Event logs.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DB2                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* Starting from DB2 V95, a package cache overflow warning      * 
* message                                                      * 
* gets logged in as ERROR in Windows Event logs as follows.    * 
*                                                              * 
* Event Type: Error                                            * 
* Event Source: DB2-0                                          * 
* Event Category: None                                         * 
* Event ID: 4                                                  * 
* Date: 21.02.2011                                             * 
* Time: 08:00:02                                               * 
* User: N/A                                                    * 
* Computer: S-BDB02                                            * 
* Description:                                                 * 
* 2011-02-21-08.00.02.327007 Instance:DB2 Node:000             * 
* PID:5716(db2syscs.exe) TID:200 Appid:*LOCAL.DB2.110221072654 * 
* access plan manager sqlra_cache_mem_please Probe:100         * 
* Database:VUINDEX                                             * 
* ADM4500W A package cache overflow condition has occurred.    * 
* There                                                        * 
* is no error but this indicates that the package cache has    * 
* exceeded the configured maximum size. If this condition      * 
* persists, you should perform additional monitoring to        * 
* determine                                                    * 
* if you need to change the PCKCACHESZ DB configuration        * 
* parameter.                                                   * 
* You could also set it to AUTOMATIC.                          * 
*                                                              * 
* It should get logged in as WARNING in the Windows Event      * 
* logs.                                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to v97f5                                             * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
in v97fp5,ADM4500W  will logged as WARNING in the Windows Event 
logs
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
07.03.2011
17.12.2011
17.12.2011
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.F5,
9.7.FP5,ADM4,
9.7.FP5,ADM4500W
Problem behoben lt. FixList in der Version
9.7.0.5 FixList