DB2 - Problembeschreibung
Problem IC75114 | Status: Geschlossen |
INSTANCE MAY CRASH WHEN A NEW DISPATCHER IS REQUIRED. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 910 - DB2 | |
Problembeschreibung: | |
When using connection concentrator, if more dispatchers are required than originally calculated to handle the concurrent connections, the instance can crash. The following message can be seen in db2diag.log before the crash : 2011-03-09-18.10.51.966610-300 I28977A644 LEVEL: Severe PID : 13402256 TID : 1 PROC : db2agent (DB8) INSTANCE: db2inst1 NODE : 000 APPHDL : 0-452 APPID: *LOCAL.db2inst1.110309231710 AUTHID : DB2INST1 FUNCTION: DB2 UDB, base sys utilities, sqeDomainSocketManager::GetDispatcherSoc, probe:10 DATA #1 : <preformatted> maxLogicalConnections = 610 maxDescriptors = 32767 numdb = 1 SQLE_CALC_NUM_DISPATCHER_PAIRS = 2 SQLE_DISPATCHER_NUM_CONNS = 500 SQLE_NUM_FREE_CONN_DESC = 32595 SQLE_APP_GROUP_NUM_DESC = 7 SQLE_NUM_RESERVED_DESC = 172 FD_SETSIZE = 32767 SQLE_MAXAGENTS_OVERFLOW = 50 The calculated number of dispatchers is given by SQLE_CALC_NUM_DISPATCHER_PAIRS. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 LUW * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 9.1 FP11 * **************************************************************** | |
Local-Fix: | |
n/a | |
verfügbare FixPacks: | |
DB2 Version 9.1 Fix Pack 11 for Linux, UNIX and Windows | |
Lösung | |
The problem is first fixed in DB2 9.1 FP11 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 18.03.2011 19.01.2012 19.01.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.1.FP11 | |
Problem behoben lt. FixList in der Version | |
9.1.0.11 |