DB2 - Problembeschreibung

Problem IC76006 Status: Geschlossen

DB2INIDB COMMAND DOES NOT DISPLAY PROPER ERROR MESSAGE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problembeschreibung:
'db2inidb' command throws following error message in case of any 
failure when issued with 'RELOCATE USING <config_file>' clause. 
 
$ db2inidb test as snapshot relocate using /..../config.out 
Relocating database... 
Unable to relocate database, cannot continue. 
$ 
 
It doesn't tell you why it is failing. It should display the 
appropriate error message.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* see APAR text                                                * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* see APAR text                                                * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* see local fix                                                * 
****************************************************************
Local-Fix:
You can get proper error message by running 'db2relocatedb' 
command with same config file as used in 'db2inidb' command as 
below: 
$ db2relocatedb -f config.out 
 
This command displays proper error message from the current 
config.out file.
verfügbare FixPacks:
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
see APAR text
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC76155 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
26.04.2011
13.03.2012
13.03.2012
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
9.5.0.9 FixList