DB2 - Problembeschreibung
Problem IC76386 | Status: Geschlossen |
BIND FILES UNDER SQLLIB/BND DIRECTORY MAY NOT GET UPGRADED BY FIXPACK INSTALL ON WINDOWS IF MODIFIED BY A SPECIAL BUILD | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 910 - DB2 | |
Problembeschreibung: | |
If a special build was applied to the system and the special build contains special versions of .bnd or .lst files under under the SQLLIB/BND folder, they may not get upgraded by the Fixpack install. This happens because the files under SQLLIB/BND are not versioned. The Windows Installer architecture will only replace unversioned files if they have not been modified since the last install. Since a special build may contain fixes in files under SQLLIB/BND, Windows Installer will not upgrade them. To avoid this issue, this APAR will introduce file versioning to the files under the SQLLIB/BND directory. This way it will enforce Windows Installer to upgrade the files regardless if they were modified or not. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users applying a Fixpack to a DB2 v9.1 install that had a * * previous special build applied * **************************************************************** * PROBLEM DESCRIPTION: * * BIND FILES UNDER SQLLIB/BND DIRECTORY MAY NOT GET UPGRADED * * BY * * FIXPACK INSTALL ON WINDOWS IF MODIFIED BY A SPECIAL BUILD * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 v9.1 Fixpack 11 * **************************************************************** | |
Local-Fix: | |
The files that were not upgraded can be manually updated by copying them from an existing install at the same Fixpack level and replacing the old files that were not upgraded properly | |
verfügbare FixPacks: | |
DB2 Version 9.1 Fix Pack 11 for Linux, UNIX and Windows | |
Lösung | |
First fixed in DB2 v9.1 Fixpack 11 | |
Workaround | |
The files that were not upgraded can be manually updated by copying them from an existing install at the same Fixpack level and replacing the old files that were not upgraded properly | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC78201 IC78202 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 13.05.2011 02.01.2012 02.01.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.1.FP11 | |
Problem behoben lt. FixList in der Version | |
9.1.0.11 |