DB2 - Problembeschreibung

Problem IC78431 Status: Geschlossen

DB2 OPTIMIZER CAN CHOOSE A SUB-OPTIMAL PLAN FOR A TABLE THAT HAS A HIGH
ROWS-PER-PAGE NUMBER

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When a table has a high rows-per-page number, DB2 optimizer can 
be too conservative with the estimate and as a result, 
prefetching may not occur for a IXSCAN-FETCH operation on such a 
table, even when the index has a high cluster ratio. This can 
result in a sub-optimal query plan.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users.                                                   * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to version 9.7 Fix Pack 6 or later.                  * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem was first fixed in Version 9.7 Fix Pack 6. 
 
The fix is not enabled by default. To enable it, set the 
following registry: 
 
DB2_EXTENDED_OPTIMIZATION=PG_CR
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC98878 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
31.08.2011
05.06.2012
28.01.2014
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP6
Problem behoben lt. FixList in der Version
9.7.0.6 FixList