DB2 - Problembeschreibung
Problem IC78850 | Status: Geschlossen |
TIMEOUT IN DB2IUPDT MAY CAUSE OPERATION TO FAIL WITH "DBI1250E APPLICATIONS ARE STILL USING THE INSTANCE" | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
Running db2iupdt to complete a fixpak or special build installation may return DBI1250E Applications are still using instance <instance name> despite the fact that the instance was shutdown and it's proven that there are no db2 processes active anymore. This issue may be caused by a too low timeout value (10 seconds) currently used in function "chk_instance_stopped" in the db2iutil script which is called by db2iupdt. It's likely to be seen when updating a large DPF instance (large = number of partitions in db2nodes.cfg). If this issue applies in your environemnt run the db2gcf utility standalone: $ timex <DB2INSTALLPATH>/bin/db2gcf -i <instance> -s -t 10 -L and check if the command returns: db2gcf Error : GCF Module function failed. and needs more than 10 seconds to complete. Then you are affected by this APAR. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Version 9.7 Fix Pack 6 * **************************************************************** | |
Local-Fix: | |
N/A | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in Version 9.7 Fix Pack 6 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 23.09.2011 02.08.2012 02.08.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP6 | |
Problem behoben lt. FixList in der Version | |
9.7.0.6 |