DB2 - Problembeschreibung

Problem IC80093 Status: Geschlossen

INCORRECT VALUES SET FOR CPU_SPEED & COMM_BANDWIDTH DURING DB2IUPDT
FAILURE.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Problem: 
Execution of installFixPack or db2iupdt commands may return the 
following warning: 
 
DBI1282W The database manager configuration files could not be 
merged. The original configuration file was saved as 
/opt/IBMdb2/home/c1adw1/sqllib/backup/db2systm.old. (The 
original instance type is ese. The instance type to be upgraded 
or updated is ese.) 
 
When DB2 fails to merge the database manager configuration 
files, CPUSPEED and COMM_BANDWIDTH might be set to values not 
reflective of the system's characteristics. These values might 
lead the query optimizer to determine suboptimal plans.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* move to next fp                                              * 
****************************************************************
Local-Fix:
If this is an existing installation, use the UPDATE DBM CFG 
command to set CPUSPEED and COMM_BANDWIDTH to the values before 
the installation activity. 
 
Otherwise set the DBM CFG parameters as the instance user: 
1) db2 update dbm cfg using CPU_SPEED -1 
2) db2 update dbm cfg using COMM_BANDWIDTH -1 
which directs DB2 to determine values appropriate to your 
system.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Fixed in v97fp6
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC84235 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
30.11.2011
26.02.2013
26.02.2013
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP6
Problem behoben lt. FixList in der Version
9.7.0.6 FixList