DB2 - Problembeschreibung
Problem IC81126 | Status: Geschlossen |
DB2 PERFORMANCE ISSUE WHEN XML DATA IS BEING USED HEAVILY. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
If XML data is being used heavily, users may experience performance issues. From the stack analysis, latch contention can be seen during XML temp table handling. Stacks may look similar to the following: 0x0900000011646384 sqloXlatchConflict + 0x284 0x090000001164603C sqloXlatchConflict@glue1A5 + 0x78 0x0900000011798380 captureLatch__12SMemBasePoolFv + 0x54 0x09000000117970BC sqlogmblkEx + 0x2D8 0x0900000011833524 sqldAllocEmptyTCB__FP8sqeAgentPP8SQLD_TCBiN23UlT3UiT8 + 0xB4 0x0900000011833238 sqldAllocEmptyTCB__FP8sqeAgentPP8SQLD_TCBiN23UlT3UiT8@glueA46 + 0x94 0x090000000DD80C5C @102@sqldCreateDAT__FP8sqeAgentPUsN32UiT6UlT8iN310_P10SQLD_FIELD P12SQLD_COLINFOP15SQLD_RCTCOLINFOT10_PiPP8SQLD_TCBPcUsN221_T6 + 0x748 0x090000001152FF50 sqldInternalCreateTable__FP8sqeAgentP19SQLD_TABLECREATE_CB + 0x3C4 0x090000001152FAB8 sqldTableCreateTemp__FP8sqeAgentPUsT2UcUlT5iP10SQLD_FIELDP12SQLD _COLINFOT7 + 0x1AC 0x090000000E4C2290 xmlsCreateTempXDA__FP8sqeAgentPP8SQLD_TCB + 0x1F0 0x090000000D8E95F4 xmls_InsertTempCSLRecord__FP11XMLSTORE_CBUiPPcPUsR8XMLS_XIDb + 0x4F0 0x090000000DD60274 flushRecord__18XmlrnTempRecordMgrFP11XMLSTORE_CBUiPPcPUsR8XMLS_X ID + 0x1F0 0x090000000D8E9F40 flush__17xmlDataDescriptorFP11XMLSTORE_CBUc + 0x340 0x090000000ECCEE50 addItemSubtree__13XmlrnSequenceFP17xmlDataDescriptor + 0x124 0x0900000010224A10 sqlriXAgg__FP8sqlrr_cb + 0x320 or 0x0900000011646384 sqloXlatchConflict + 0x284 0x090000001164603C sqloXlatchConflict@glue1A5 + 0x78 0x0900000011798380 captureLatch__12SMemBasePoolFv + 0x54 0x0900000011797708 sqlofmblkEx + 0x180 0x09000000118412A4 sqldFreeTCB__FP16sqeLocalDatabaseP8SQLD_TCB + 0x980 0x090000001184237C sqldDelTCB__FP8sqeAgentP16sqeLocalDatabaseP8SQLD_TCB + 0xCC 0x0900000011841FFC sqldDropTable__FP8sqeAgentP12SQLB_GLOBALSP8SQLD_TCBi + 0x174 0x090000000E0C1F28 sqldDropTable__FP8sqeAgentP12SQLB_GLOBALSP8SQLD_TCBi@glue3C4 + 0x78 0x090000000E068028 sqldTableDrop__FP8sqeAgentUsT2UciPcT5T6T5 + 0x1EC 0x090000001156B108 sqldTableDrop__FP8sqeAgentUsT2UciPcT5T6T5@glueC6F + 0xA0 0x090000000E06CD20 sqlricls_complex__FP8sqlrr_cbilN23 + 0x818 0x09000000116B0F1C sqlricls_complex__FP8sqlrr_cbilN23@glue852 + 0x78 0x09000000116AB6D0 sqlrr_process_execute_request__FP8sqlrr_cbi + 0xAA8 0x09000000116ABBD4 sqlrr_execute__FP14db2UCinterfaceP9UCstpInfo + 0x21C 0x090000000F9995EC executeSection__10pvmPackageFP5sqlcaUib + 0x674 | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All user on DB2 V97 Fp6 and earlier * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 V97 FP7 * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Lösung | |
First Fixed in DB2 V97 FP7 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC84605 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 31.01.2012 02.11.2012 02.11.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP7 | |
Problem behoben lt. FixList in der Version | |
9.7.0.6 | |
9.7.0.7 |