DB2 - Problembeschreibung
Problem IC85738 | Status: Geschlossen |
SLOW ETHERNET FAILOVER OF PRIMARY CF ROLE | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
Problembeschreibung: | |
If an ethernet failure occurs, the primary CF role will take a long time to failover. It can take up to 2 minutes from the time of failure until the primary CF role is restarted. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 PureScale users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 V10.1 FP1 * **************************************************************** | |
Local-Fix: | |
Set the tcp_keepinit value on the CF host to 10 seconds (from the default 75 seconds) | |
verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 1 for Linux, UNIX, and Windows | |
Lösung | |
The fix will be included in DB2 V10.1 FP1 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 04.08.2012 07.11.2012 07.11.2012 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.1.0.1 | |
10.5.0.1 |