DB2 - Problembeschreibung

Problem IC85740 Status: Geschlossen

LOAD INSERT INTO MDC TABLE WITH COMPRESS ENABLED BUT NO DICTIONARY EXISTS
YET, AND IS INTERRUPTED, MIGHT TRAP/SEG-FAULT.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
If a table is enabled for Compression, but no dictionary exists 
yet, and the table contains existing data, and a Load INSERT is 
invoked, then Load's Automatic-Dictionary-Creation logic may 
attempt to sample existing data in the table. If the table is an 
MDC table and this Load is interrupted, in some timing 
situations this could cause a trap or seg-fault. 
 
Symptoms include a trap file with the following stack: 
 
<StackTrace> 
... 
sqloEDUCodeTrapHandler 
sqlbfix 
sqlbFixPage 
sqluFixPage 
sqluMDCFixBMP 
sqlulAdcTableScanner 
sqluCTableScanner 
sqluLoadEDUDriver 
 
OR similar stack but with sqlbufix instead of sqlbfix, for 
example: 
... 
sqlbufix 
sqluMDCUnfixBMP 
sqlulAdcTableScanner 
sqluCTableScanner 
sqluLoadEDUDriver
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DB2 V9.7 Fix pack 7 and below                                * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 v9.7 Fix pack 8                               * 
****************************************************************
Local-Fix:
Perform a Load TERMINATE and then re-execute the original Load 
without interrupting it.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 V9.7 Fix pack 8
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
06.08.2012
02.04.2013
25.07.2014
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP8
Problem behoben lt. FixList in der Version
9.7.0.8 FixList