DB2 - Problembeschreibung

Problem IC86068 Status: Geschlossen

SYSTEM MODULE ROUTINE DBMS_ALERT.REGISTER MAY INCORRECTLY REMOVE ACTIVE
ALERTS.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
The system module DBMS_ALERT is used to send alerts between 
applications. 
 
Each alert must be registered with the DBMS_ALERT.REGISTER 
routine. 
If an application disconnects, then any alerts that were 
associated to that application are no longer active. 
 
During the register process, db2 will clean up any old alerts 
from previous applications that have since disconnected. 
However, if multiple alerts are registered from different 
applications concurrently with specific timing, then there is a 
logic problem that might (depending on specific timing) result 
in removing an active registered alert for an application that 
is currently connected.  This will result in the failure to 
signal or wait for the alert that was incorrectly removed. 
 
The problem is more likely to occur on (but not limited to), a 
DPF instance.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to v97 fixpack 7.                                    * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem fixed in v97 fixpack 7.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC86092 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
22.08.2012
20.10.2012
20.10.2012
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP7
Problem behoben lt. FixList in der Version