DB2 - Problembeschreibung
Problem IC87079 | Status: Geschlossen |
SQLGETCONNECTATTR() WITH SQL_ATTR_PING_DB AFTER A SEAMLESS FAILOVER | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
Problembeschreibung: | |
If your are using SQL_ATTR_PING_DB with SQLGetConnectAttr() and a seamless failover takes place after this call, a value of 0 is returned instead of a Warning even if SQL_ATTR_REPORT_SEAMLESSFAILOVER_WARNING is set to YES. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * DB2 CLI users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 v101 FP3 or later * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
The problem is first fixed in DB2 v101 FP3 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 09.10.2012 07.10.2013 07.10.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.1.0.3 | |
10.1.0.3 |