DB2 - Problembeschreibung

Problem IC90682 Status: Geschlossen

STMM ON 32-BIT INSTANCE PLATFORM MAY FAIL TO UPDATE PCKCACHESZ WHEN IT IS
WORKING ON 64-BIT WINDOWS

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When DB2 STMM is working for a database of db2 32-bit instance 
on 64-bit Windows, DB2 STMM fails to update PCKCACHESZ db cfg 
parameters with over limited value for 32-bit instance as below. 
 
2013-02-13-13.27.12.006000+540 I1152713H977       LEVEL: Event 
PID     : 8052                 TID  : 7536        PROC : 
db2syscs.exe 
INSTANCE: DB2                  NODE : 000         DB   : DB01 
APPHDL  : 0-20                 APPID: *LOCAL.DB2.130213025200 
AUTHID  : DB2ADMIN 
EDUID   : 7536                 EDUNAME: db2stmm (DB01) 
FUNCTION: DB2 UDB, Self tuning memory manager, 
stmmLogRecordBeforeResizes, probe:590 
DATA #1 : String, 525 bytes 
 
***  stmmCostBenefitRecord *** 
Type: PCKCACHESZ 
PageSize: 4096 
Saved Misses: 11 
Benefit: 
  -> Simulation size: 8913 
  -> Total seconds saved: 2 (+ 326322613 ns) 
  -> Normalized seconds/page: 1.32525E-006 
Cost: 
  -> Simulation size: 8913 
  -> Total seconds saved: 2 (+ 326322613 ns) 
  -> Normalized seconds/page: 1.32525E-006 
Current Size: 89122 
Minimum Size: 2095 
Potential Increase Amount: 44561 
Potential Increase Amount From OS: 44561 
Potential Decrease Amount: 17824 
Pages Available For OS: 17824 
Interval Time: 196.947 
 
2013-02-13-13.27.12.022000+540 I1156264H635       LEVEL: Error 
PID     : 8052                 TID  : 7536        PROC : 
db2syscs.exe 
INSTANCE: DB2                  NODE : 000         DB   : DB01 
APPHDL  : 0-20                 APPID: *LOCAL.DB2.130213025200 
AUTHID  : DB2ADMIN 
EDUID   : 7536                 EDUNAME: db2stmm (DB01) 
FUNCTION: DB2 UDB, Self tuning memory manager, 
stmmUpdateDBConfig, probe:275 
MESSAGE : ZRC=0x82AE00A7=-2102525785=STMM_CONFIG_UPDATE_FAILED 
          "An attempted configuration update failed" 
DATA #1 : String, 74 bytes 
Error updating parameter Pckcachesz, updateValue = 133683, 
sqlcode = -5131
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* 32-bit instance user on 64-bit Windows                       * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 version 9.7 fixpack 9                         * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem was first fixed in DB2 version 9.7 fixpack 9
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC95429 IC95528 IC95659 IC96271 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
06.03.2013
24.12.2013
24.12.2013
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP9
Problem behoben lt. FixList in der Version
9.7.0.9 FixList
9.7.0.9 FixList