home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Neueste VersionenFixList
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

DB2 - Problembeschreibung

Problem IC91246 Status: Geschlossen

HADR PRIMARY DISCONNECTS AND STANDBY SHOWS PEER STATE WHEN DISK IS FULL ON
STANDBY.

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
HADR primary disconnects and standby shows peer state when disk 
is full on standby. 
 
On HADR standby, you can see the following error messages in 
db2diag.log file: 
 
2013-02-18-03.38.48.605355-360 I15634A387         LEVEL: Error 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgifl, probe:50 
RETCODE : ZRC=0x850F000C=-2062614516=SQLO_DISK "Disk full." 
          DIA8312C Disk was full. 
... 
 
2013-02-18-03.53.28.302067-360 I47492A448         LEVEL: Info 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgStartMfhEntry, 
probe:7240 
DATA #1 : <preformatted> 
Dual log array is full.  Checking if any new logs have been 
archived. 
end: 6139, lowestUnarchivedExtNum: 6074, path: 9
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* First fixed in DB2 Version 9.7 Fix Pack 9                    * 
****************************************************************
Local-Fix:
Clear the disk full situation and restart the HADR standby.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 Version 9.7 Fix Pack 9
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC97543 IC97550 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
02.04.2013
17.12.2013
25.04.2014
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP9
Problem behoben lt. FixList in der Version
9.7.0.9 FixList
9.7.0.9 FixList