DB2 - Problembeschreibung
Problem IC91755 | Status: Geschlossen |
HMONSQLCONNECT, PROBE:100 ERROR WAS OCCURRED. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
Problembeschreibung: | |
hmonSQLConnect, probe:100 error was occurred. db2diag.log was recorded as below. 2012-07-15-14.26.07.346109+540 I7693633E291 LEVEL: Severe PID : 18140 TID : 1094363456 PROC : db2acd INSTANCE: db2inst1 NODE : 000 FUNCTION: DB2 UDB, Health Monitor, hmonSQLConnect, probe:100 MESSAGE : SQLGetCurrentCtx error sqlRC=[0] sqlcode[-1442] hmonSQLConnect is using freed context, so hmonSQLConnect is recording this entry. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 UDB version 10.1 fixpack 3. * **************************************************************** | |
Local-Fix: | |
Restart instance then activate database. | |
verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in DB2 UDB Version 10.1 FixPack 3. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 22.04.2013 08.10.2013 08.10.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.1.0.3 | |
10.1.0.3 |