DB2 - Problembeschreibung
Problem IC95642 | Status: Geschlossen |
CLI0106E ERROR OCCURS DUE TO PHYSICAL NETWORK TIMEOUT BY LONG IDLE TIME | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
Problembeschreibung: | |
When under connection pooling, the application can get a connection via OCISessionGet() that is no longer active because of the tcpip keep alive processing which terminated a connection that was idle for more than the default interval (2 hours). CLI does not detect this either as no indication that the connection has been terminated is ever given to the client at any layer. The only way to verify this for sure was to capture a DB2CI trace with TraceTimestamp=1 to see that a given connection was not used in over 2 hours or trace tcpip itself (not sure how to do this). | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 10.1 Fix Pack 4 * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
First fixed in Version 10.1 Fix Pack 4 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Bug-Verfolgung | |
Vorgänger : APAR is sysrouted TO one or more of the following: IC97096 Nachfolger : | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 01.09.2013 21.10.2013 21.10.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.1.0.3 | |
10.1.0.3 |