Problem IC96003 Status: Geschlossen

When doing switch user in a trusted connection, the client omits to send
User Registry Name (USRREGNM) to the database server

Produkt:
DB2 CONNECT / DB2CONNCT / 970 - DB2
Problembeschreibung:
When an application switches the user ID for an explicit trusted 
connection then any User Registry Name that is associated with 
the connection is incorrectly omitted from data the client sends 
to the database server. 
 
Applications that use the CLI (Call Level Interface) API can 
associate a User Registry Name to the connection 
by assigning a value to the the CLI environment handle or 
connection handle attribute SQL_ATTR_USER_REGISTRY_NAME before 
it connects to a database. 
 
If the User Registry Name is set then it ought to be included as 
the USRREGNM (User Registry Name) attribute of DDM 
(Distributed Data Management) commands that are sent to the 
database server. 
 
When the User Registry Name is missing from the data sent by the 
client that can cause errors such as "DISTRIBUTED IDENTITY IS 
NOT DEFINED" and "378-014 ABEND DURING RACINIT PROCESSING" on a 
DB2 on z/OS database server. 
 
This defect affects DB2 for Linux, UNIX and Windows both as a 
database client and as a database gateway (DB2 Connect).
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Users of DB2 for Linux, UNIX and Windows applications that   * 
* use the CLI (Call Level Interface) API to connect to a       * 
* database using an explicit trusted connection                * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* .                                                            * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem was first fixed in Version 9.7 Fix Pack 9 
At a minimum, this fix should be applied on the client and any 
DB2 Connect gateway.
Workaround
keiner bekannt / siehe Local-Fix
Bug-Verfolgung
Vorgänger  : APAR is sysrouted TO one or more of the following: IC96146 IC96155 
Nachfolger : 
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
17.09.2013
17.12.2013
17.12.2013
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP9
Problem behoben lt. FixList in der Version
9.7.0.9 FixList