DB2 - Problembeschreibung
Problem IC96257 | Status: Geschlossen |
POSSIBLE ABEND DURING SQLCONNECT CALL WHEN CONNECTIONS ARE FORCED ON THE SERVER SIDE. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
Problembeschreibung: | |
The following stack trace can be observed in the client application. SQLConnect2 SQLDriverConnect2 SQLConnect1 SQLConnect The problem is very timing sensitive and there needs to be an action on the server side that raises a connection error whilst the client code is processing the SQLConnect call. e.g. a force applications all or a quiesce database immediate force connections | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade the database server to V10.1 Fix Pack 3 * **************************************************************** | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows | |
Lösung | |
This problem was first fixed in DB2 V10.1 Fix Pack 3 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 25.09.2013 21.10.2013 21.10.2013 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.1.0.3 | |
10.1.0.3 |