Problem IC96713 Status: Geschlossen

CLI0113E ERROR OCCURS ON TIMESTAMP LITERAL VALUE FOR OUTPUT PARAMETER OF
STORED PROCEDURE WHEN IMPLICIT CAST IS DISABLED

Produkt:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problembeschreibung:
The following error may occur from a CLI/ODBC application when 
calling a stored procedure with a timestamp supplied as a 
literal value for an output parameter: 
CLI0113E  Invalid date/time format 
 
This works fine when when the implicit cast feature is enabled 
but when it is disabled (via DB2 for z/OS APAR PM77180), and 
any datatype mismatch, server hit -301 error and cli will retry. 
while retrying validation is being done on the timestamp literal 
value that is supplied for the output parameter.  If the value 
supplied is not a valid timestamp value (For example, an empty 
string '') the CLI0113E error will occur. 
 
This APAR will replace the output literal value to a null 
indicator even when the parameter is not bound but has the 
values supplied during call.  This will avoid the CLI0113E error
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All DB2 CLI users                                            * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* upgrade to v10.5.3 and later                                 * 
****************************************************************
Local-Fix:
As a workaround, supply a value for the timestamp output 
parameter that has a valid timestamp format.
verfügbare FixPacks:
DB2 Cancun Release 10.5.0.4 (also known as Fix Pack 4) for Linux, UNIX, and Windows
DB2 Version 10.5 Fix Pack 9 for Linux, UNIX, and Windows

Lösung
fixed in v10.5.3 and later
Workaround