DB2 - Problembeschreibung

Problem IC97550 Status: Geschlossen

HADR PRIMARY DISCONNECTS AND STANDBY SHOWS PEER STATE WHEN DISK IS FULL ON
STANDBY.

Produkt:
DB2 FOR LUW / DB2FORLUW / A10 - DB2
Problembeschreibung:
HADR primary disconnects and standby shows peer state when disk 
is full on standby. 
 
On HADR standby, you can see the following error messages in 
db2diag.log file: 
 
2013-02-18-03.38.48.605355-360 I15634A387         LEVEL: Error 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgifl, probe:50 
RETCODE : ZRC=0x850F000C=-2062614516=SQLO_DISK "Disk full." 
          DIA8312C Disk was full. 
... 
 
2013-02-18-03.53.28.302067-360 I47492A448         LEVEL: Info 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgStartMfhEntry, 
probe:7240 
DATA #1 : <preformatted> 
Dual log array is full.  Checking if any new logs have been 
archived. 
end: 6139, lowestUnarchivedExtNum: 6074, path: 9
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 Version 10.1 Fix Pack 4                       * 
****************************************************************
Local-Fix:
Clear the disk full situation and restart the HADR standby.
verfügbare FixPacks:
DB2 Version 10.1 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 10.1 Fix Pack 6 for Linux, UNIX, and Windows

Lösung
First fixed in Version 10.1 Fix Pack 4
Workaround
keiner bekannt / siehe Local-Fix