DB2 - Problembeschreibung

Problem IT04362 Status: Geschlossen

SQLCODE -302 IS RETURNED DURING STATIC SQL EXECUTION INSTEAD OF BIND/REBIND

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
Binding or rebinding a static application should detect invalid 
host variable information (such as a DECIMAL with precision 0) 
and return SQLCODE -302. 
In some circumstances, the invalid host variable information may 
not be detected at bind/rebind, and is recorded in the section. 
 
This results in SQLCODE -302 at execution time instead.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 version 9.7 fix pack 11                       * 
****************************************************************
Local-Fix:
Ensure host variable information is valid
Lösung
First fixed in DB2 version 9.7 fix pack 11
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
12.09.2014
19.10.2015
19.10.2015
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP11
Problem behoben lt. FixList in der Version
9.7.0.11 FixList